Energy · Flanders

Reading a digital meter: what do the numbers and codes mean?

Learn to read your digital meter: consumption, export, kWh, kW and display codes. With an example and guidance on Mijn Fluvius, P1 and smart energy use.

By · managing director at Wattra · · 6 min. read

The short answer

Your digital electricity meter shows how much electricity you draw from the grid and how much you send back. Always read three things together: the code, the number and the unit. A reading in kWh is a cumulative amount of energy; kW describes power. Mijn Fluvius shows your history, while a suitable P1 application provides near-live monitoring.

Before you start

Practical guidance for Fluvius digital electricity meters in Flanders. The screen order, symbols and available readings vary by meter model.

How to read a single display screen

Code 1.8.1

003248.650 kWh

Example value, not your meter data. Read this as 3,248.650 kWh on the daytime import register. It is not one day’s consumption or an amount in euros.

In this article

The main display codes

Always read the code together with the unit. Meter models do not all show the same screens in the same order.

1.8.1
Electricity imported from the grid on the daytime register, in kWh.
1.8.2
Electricity imported from the grid on the night-time register, in kWh.
2.8.1
Electricity exported to the grid on the daytime register, in kWh.
2.8.2
Electricity exported to the grid on the night-time register, in kWh.
1.8.0
Total electricity imported: daytime and night-time combined, in kWh, if your meter shows this screen.
2.8.0
Total electricity exported: daytime and night-time combined, in kWh, if this screen is available.
1.7.0
Power currently being drawn from the grid, in kW, on meters with this display.
2.7.0
Power currently being exported to the grid, in kW, on meters with this display.
1.6.0
Highest average power drawn from the grid over a quarter-hour in the current month, in kW, if your meter displays it.

Sources: Fluvius — manuals for all digital electricity meters, Fluvius — Sagemcom S211/T211 manual

Start with the code, not the largest number

Find the small code first, then read the unit. On common Sagemcom and Landis+Gyr meters, a short press of the control button lights the display; further short presses cycle through the screens. Button colour and screen order vary by model. Do not simply hold the button down: that may activate a different function. Do not open sealed parts.

Need help reading the display? Take a photo showing the code, value and unit together, and note the time. A photo of the large number alone does not provide enough information. Do not share it publicly with unnecessary address or connection details.

Sources: Fluvius — Sagemcom S211/T211 manual, Fluvius — Landis+Gyr E360 manual, Fluvius — choose the manual for your meter model

Imports and exports: two directions, not a single balance

Import is electricity flowing from the grid into your installation. Export is electricity your installation supplies to the grid, such as surplus solar electricity. The digital meter records these directions separately. Do not simply subtract one reading from the other to determine what your supplier will charge.

If you have solar panels, grid imports are not the same as your home’s total electricity consumption. Solar electricity used directly is not recorded as a grid import. Exports are not your total solar generation either. In a simple example without a battery, you generate 4 kWh, use 3 kWh immediately and export the remaining 1 kWh to the grid. Always compare meter and inverter readings over the same period.

Sources: Fluvius — Sagemcom S211/T211 manual

A meter reading is not your consumption for today

A register measured in kWh accumulates over time. To examine a period, compare the starting and ending readings of the same register. For total grid imports, add the increase in each of the two import registers, or use the increase in the total import register if available.

Example using fictional readings: the daytime register rises from 1,400 to 1,406 kWh and the night-time register from 600 to 602 kWh. You imported 6 + 2 = 8 kWh from the grid during that period. Note both timestamps so that you do not accidentally compare a full day with half a day. Calculate exports separately; do not mix the registers.

Sources: Fluvius — manuals for all digital electricity meters

kW and kWh: power at a moment versus total energy used

kW describes the power being drawn or supplied at a particular moment. kWh measures energy over a period. An appliance drawing a constant 2 kW for half an hour uses 1 kWh. A power rating of 2,000 watts is the same as 2 kW.

A brief high reading is not automatically your monthly peak. For the Flemish capacity tariff with a digital meter, the highest average power drawn from the grid over a quarter-hour during the month is relevant. Check Mijn Fluvius for monthly peaks; the applicable rules include an exception for households on the social tariff. The current kW reading is therefore not a direct cost counter in euros.

Sources: Vlaamse Nutsregulator — the capacity tariff

Why are daytime and night-time readings shown with a single-rate tariff?

The digital meter continues to record daytime and night-time readings even if you have a single-rate tariff. In that case, the quantities are combined for that tariff. Having two registers does not prove that you pay two different energy prices.

Check your contract or tariff sheet for the pricing terms. Do not multiply every kWh ever recorded by the price shown today. Your bill depends on the relevant period, meter data, contract terms and grid charges, among other things.

Sources: Fluvius — Landis+Gyr E360 manual

When should you use the display, online records or P1?

The display is useful for a quick on-site check. Mijn Fluvius provides free charts and reports after you register and request access to your consumption data. It updates daily; the portal does not show a live response to an appliance you have just switched on. Accessing someone else’s data requires permission.

For near-live monitoring, use a suitable application connected through the P1 user port. Fluvius describes electricity data being available every second. Have the port activated and choose who receives access. A metering dongle is not automatically a complete energy-management system: the app, control equipment and EV charger or battery must be able to work together.

Sources: Fluvius — monitor your energy consumption online, Fluvius — user port and smart applications

How can you use this information?

Start with a specific question. Do you want to know why grid imports are higher in the evening? Compare the same time slots and note which appliances were used. A refrigerator, ventilation system or heating may legitimately need to keep running; a constant base load is not entirely waste. Do not switch off essential equipment just to achieve a zero reading.

Planning an EV charger, home battery or heat pump? Gather grid import, export and usage-time data over a representative period. One sunny afternoon or one high peak does not determine a suitable battery capacity. Discuss changes too, such as getting an electric car. With this information, Wattra can prepare a more focused technical assessment and quote without promising a fixed saving in advance.

What do the lights, symbols and numbers mean?

Alongside the readings, you will find details such as the model and serial numbers. Depending on the meter, symbols also indicate the direction of electricity flow, communication status or an activated user port. Check the correct manual for their exact location and meaning. A serial number identifies the meter; it is not a consumption reading.

A flashing indicator light can indicate either imports or exports. Faster flashing therefore does not prove that your home is suddenly drawing more electricity from the grid. Read the corresponding direction and kW value. A missing communication symbol is not a reason to disconnect wiring yourself either.

Sources: Fluvius — Sagemcom S211/T211 manual

Who can help with an unclear display or a fault?

Contact Fluvius with questions about the meter, its communication or registration. An unexpected reading does not automatically mean a fault: first check the code, unit and period. Differences between a supplier’s app and Mijn Fluvius may also relate to update times or the period displayed.

Is your question about your own electrical installation, suitable controls, an EV charger or a home battery? Wattra helps customers in Sint-Niklaas, the Waasland and throughout Flanders. Send your question, municipality, a photo of the display and what you want to achieve. Do not share itsme codes, account passwords or identity documents. Wattra does not replace or open sealed Fluvius meters.

What you can prepare now

  • Read the code, number and unit together.
  • Record imports and exports separately, with the date and time.
  • Compare the same period, and do not add kW to kWh.
  • Use Mijn Fluvius to identify patterns and P1 for near-live monitoring.
  • Tell us which problem or installation choice you want to investigate.

Frequently asked questions

Why does my meter reading increase when I have solar panels?

You draw electricity from the grid when your installation needs more than is available locally. Also check the separate export register. Grid imports and solar generation are different measurements.

Does my meter show how much electricity each appliance uses?

No. The grid meter shows the electricity exchanged between the connected installation and the grid. A P1 app can help identify patterns, but individual appliances may require additional metering.

Does 0 kW mean that no electricity is being used in my home?

Not necessarily. Your own generation or a battery may be covering the home’s consumption at that moment. No grid import does not mean no electricity use.

Do the same display codes apply to my gas meter?

No. This overview covers electricity. A digital gas meter has its own controls and shows the gas reading in m³; this is not the same as the kWh on your gas bill. Use the manual for your particular gas meter.